The set pressure for API Plan 32 is a function of the seal chamber pressure (Ps). The Plan 32 flush pressure should be set approximately 15 – 30 psi over the max seal chamber pressure. The seal chamber pressure can be calculated here. Additional information on Plan 32 can be found here.